Main Features
- Models can be chosen to accomodate from 2 to 14 racks (see table at right for rack capacity)
- Stainless steel exterior with 300 Series s/s interior and
aluminized steel top
- Foamed insulation in walls ceilings and doors
- Modular wall and ceiling panels with cam lock
construction
- Heavy duty welded s/s hinges
- Rapid responding air-wash heat and humidity system
- 208/240 VAC, either 1 or 3-phase, field convertible
- Dual purpose, provides both retarding and proofing
- 70° - 120° F proofing range
- 34° - 45° F retarding range
- 50 - 99% humidity range
- Non-submerged calrod type heaters
- Evaporators sized for high humidity levels (prevents drying)
- Refrigeration system sized for rapid pull-down
- Refrigeration components compliant with R404a refrigeration
- Interior/exterior bumpers
- Lighted interior
- Digital set Temperature, Humidity, Time
- Operates in individual mode or automatic mode
- PID type controls for rapid accurate response without
overshoot
- Large LED display
- All digital controls mounted in the door at eye-level
- ETL Certified. Meets UL-197, NSF-8 and CSA C22.2 standards
- One year parts and labor warranty
Note: BARP-1, BARP-2 and BARP-3 offer the same Construction, Operation, and Control features
Options
- Stainless steel floor
- Refregeration condenser (requires separate connection)
- Prison package
- Pass-through model
Dimensions
- Front-to-back overall depth varies from approx 45" - 125" according to model. Add 7" for pass-through
- Outside width: 103" (2" clearance required at both sides for doors to open 90°)
- Height: 92"
- Height with ceiling mounted condenser: 105"
- Normally shipped knock-down. When disassembled, can fit through 36" opening
Electrical
- For Models BARP-2-30 to BARP-2-80:
-
208V/60/1, 24 Amps, 5 kW
- 240V/60/1, 27.5 Amps, 6.6 kW
- 208V/60/3, 13.8 Amps, 5 kW
- 240V/60/3, 15.8 Amps, 6.6 kW
- For Models BAP-2-90 to BAP-2-120:
-
208V/60/1, 48 Amps, 10.2 kW
- 240V/60/1, 55 Amps, 13.2 kW
- 208V/60/3, 27.6 Amps, 10.2 kW
- 240V/60/3, 31.6 Amps, 13.2 kW
- If chosen, condenser requires separate connection
Installation
- Requires on site installation
See Spec Sheet for diagrams, measurements, and installation details |

Downloads
Model/Rack Capacity*
In the table below, for example BARP-2-80 refers to a double door BARP retarder proofer that is approx 80 inches from front to back. See Spec Sheet for other measurements and diagrams.
| Model |
Side Load
28.4”x18.0” |
End Load
26.0”x20.4” |
Double
28.4”x36.0” |
| BARP-2-30 |
2 Rack |
3 Rack |
N/A |
| BARP-2-40 |
4 Rack |
3 Rack |
2 Racks |
| BARP-2-50 |
5 Racks |
5 Racks |
2 Racks |
| BARP-2-60 |
6 Racks |
6 Racks |
3 Racks |
| BARP-2-70 |
7 Racks |
7 Racks |
3 Rack |
| BARP-2-80 |
9 Rack |
8 Rack |
4 Racks |
| BARP-2-90 |
10 Racks |
10 Racks |
5 Racks |
| BARP-2-100 |
11 Racks |
10 Racks |
5 Racks |
| BARP-2-110 |
12 Racks |
13 Racks |
5 Racks |
| BARP-2-120 |
14 Racks |
13 Racks |
7 Racks |
*Racks may be snug at maximum capacity. For diagrams
of rack arrangement, see the Rack Capacity Guide |